Power panel

Sentinel samples PMBus POUT registers in a dedicated thread. The default interval is 100 ms. The normal cache interval is slower, so the UI publishes the latest accumulated state rather than displaying every raw PMBus sample.

Headline fields

FieldCalculation
CurrentSum of rails successfully read during the latest PMBus pass that had at least one successful rail.
Session averageArithmetic mean of all valid total samples since daemon start. A pass is considered valid when at least one rail succeeds.
Session peakMaximum valid total sample since daemon start.
DurationElapsed monotonic time since the power accumulator started.
Valid samplesPMBus passes in which at least one configured rail was read.
Failed samplesPMBus passes in which no configured rail was read.

All session statistics reset when the daemon restarts.

Collector states

  • ACTIVE: at least one valid sample exists, the latest pass had data, and there is no current rail error.
  • DEGRADED: valid data exists, but the latest pass failed completely or at least one rail reported an error.
  • UNAVAILABLE: no valid total has been collected.

During a partial failure, Current, Average, and Peak totals can contain fewer rails than a healthy sample. If a pass fails completely, Current and all rail Power values retain their last successful readings; Failed samples and rail Errors increase, and the state becomes DEGRADED. Do not interpret retained values as measurements from the failed pass or compare partial and complete totals as if they measured the same boundary.

Rail table fields

  • Power is the most recent successful reading for that rail. If a later read fails, this value remains at the last success while Errors increments.
  • Samples counts successful readings for that rail since daemon start.
  • Errors counts failed page-select or PMBus-register reads for that rail.

For a partially successful pass, the total uses only rails that succeeded in that pass while each rail row retains its last successful value. For a completely failed pass, both the total and rail rows retain earlier values. Consequently, summing visible rail rows can differ from Current during a partial failure, and neither value is fresh after a complete failure.

Modalix SOM rails

RailWhat it supplies
SoC and DDR VDDMain SoC and DDR domain; SoC logic, memory-controller, and DDR activity contribute.
HDMI 1.2VHDMI 1.2 V PHY and related circuitry.
SoC and DDR VDDQDDR I/O signaling domain between the memory controller and DDR devices.
SoC and DDR VDD2HAdditional SoC/DDR memory power domain.
MLA 0.68V0.68 V MLA core supply and the rail most directly associated with MLA compute.
PCIe and ETH VPPCIe and Ethernet PHY/platform domain.
SOM Platform 1.8VShared 1.8 V SOM platform and peripheral circuitry.
SOM Platform 3.3VShared 3.3 V SOM platform and peripheral circuitry.

SoC and DDR VDD and MLA 0.68V have a 0.25 W reporting step. The other standard SOM rails have a 0.03125 W step. Therefore, 0.00 W with increasing Samples and zero Errors is a valid zero-valued register reading at the rail's resolution, not a sensor-read failure.

The Modalix DVT profile exposes only DVT PMIC 0x4d page0. Its total is not directly comparable to the eight-rail SOM total.

Measurement boundary

Current is monitored board-rail power, not AC wall power or complete system input power. It can exclude unmonitored rails, regulator losses, carrier-board components, storage, fans, and host-side devices.

Likewise, model energy is not represented by MLA 0.68V alone. Inference also uses DDR, SoC, and platform rails. Record the profile, rail health, Sentinel version, workload window, and ambient/board conditions when comparing runs.